Material Characterisation
  1. User Fee Details
  2. Characterization Form - Physics
fac
Powder X-ray Diffractometer
  1. PANalytical X’Pert PRO powder X-ray Diffractometer
  2. 15KVA UPS support
fac
Micro Raman Spectrometer
  1. Imaging Spectrograph STR 500 mm Focal Length Laser Raman spectrometer
  2. Flat field : 27 mm(W) × 14 mm(H)
  3. Resolution : 1 / 0.6cm-1/pixel
fac
Photo Luminescence
  1. Varian Cary Eclipse Photo Luminescence
  2. Spectrophotometer
  3. Oxford Low temperature LN2 77K set up
  4. High temperature 100 373K arrangement
fac
FTIR spectrophotometer
  1. Model: Thermo Nicolet 380 FTIR spectrophotometer
  2. Wavelength range is 4000 to 400 cm-1
  3. Detector: DLaTGS detector
  4. Resolution: 0.5 cm-1
  5. S/N ratio: 2000:1 ppm for 1 minute scan
  6. Wavelength accuracy: 0.01 cm-1
fac
UV-Vis-NIR spectrophotometer
  1. UV-DRS-spectrophotometer
  2. Thermofisher Evaluation 220
  3. 190-1100nm rangep
fac
Surface Profilometer - Thickness and surface roughness measurement
  1. SJ-301 Mitutoyo Surface Profilometer
  2. Thickness and surface roughness measurement
fac
SOLAR SIMULATOR
  1. Lamp irradiance: 1000 watts/m2 or above
  2. Type of lamp: LED Source
  3. Illumination area: 9 cm2
  4. I-V SYSTEM: Keithley system (model:2401)
fac
SIMULTANEOUS DSC-TGA
  1. Ambient to 1500 Deg C
  2. Heating Rates from 0.1 to 100°C/min up to 1000°C & 25°/min till 1500°C
  3. DSC sensitivity: 4 Microwatts
  4. Weighing Accuracy /Precision: 0.005%/ 0.002%
fac
Vibrating Sample Magnetometer
  1. Vibrating Sample Magnetometer with 4” (2.2 Tesla @ Room temperature) high temperature performance electromagnet
fac
Atomic Force Microscope
  1. AFM 5100 Agilent Atomic Force Microscope with contact and non-contact modes, and tapping and mapping facilities
fac
CH- Instrument – Electrochemical Work Station
  1. Electro chemical work station
fac
Auto lab - Electrochemical impedance spectroscopy
  1. Auto lab Frequency Response analysis
  2. (Interfaced)
  3. Electrochemical impedance spectroscopy
fac
Four Probe Resistivity measurement
  1. Linear Four Probe Resistivity measurement
  2. Keithley 2000 multimeter
fac
Solar Simulator I-V/C-V
  1. Solar Simulator I-V/C-V & Pulsed I-V characterization system
fac
Scanning potentiostat/Galvanostat
  1. Scanning potentiostat/Galvanostat
  2. PAREG&G,USA
fac
DC, RF & Pulsed sputtering
  1. DC, RF & Pulsed sputtering with mass flow control
  2. Advance Tech. with 5 KVA support
  3. Substrate heater up to 800°C
  4. PAREG&G,USA
fac
Thermal & Electron beam evaporation
  1. Vacuum coating unit
  2. Thermal evaporation
  3. Electron beam evaporation
fac
Spin coater
  1. Spin coater
fac
Planetary Ball-miller
  1. Retsch - Planetary Ball-miller PM 100
  2. Type C grinding bowls
  3. Maximum feed volume 250ml
  4. Maximum feed grain size upto< 6 mm
fac
Photoacoustic spectrometer
  1. Photoacoustic spectrometer
  2. Indigeneously integrated
  3. Xenon source
  4. Chopper
  5. Standard Lock-in-amplifier
fac
Tubular Furnace
  1. Tubular Furnace
  2. Two zones
  3. Heating range upto 1200
  4. Inert gas atmosphere
fac
Glove box
  1. Glove box
  2. Inert atmosphere set up for Li-Battery fabrication
  3. < 6ppm H2O
fac
Cryogenic constant temp. bath
  1. Computer controlled cryogenic constant temperature bath
  2. Temperature range 10°C to 75°C
  3. CFC refrigeration system
fac
Czochralski Crystal Puller
  1. High Temperature (1200°C ) Czochralski Crystal Puller
  2. Pulling Speed : 0.3mm/hr to 15mm/hr
  3. Crystal Rotation Rate : 1 – 25rpm
  4. Growth Atmosphere – Argon and Oxygen – 2atm
fac
Split tube single zone furnace
  1. THERMOLYNE- F 79440-33 Split tube single zone furnace
  2. Programmable (PID) with indicator controller backed by Thyrister control
  3. Multi programmable 4 stored programmer of 8 ramp and 8 dwells
  4. Working temperature range: 100 °C -1200 °C
fac
Optical Microscope
  1. ATC 2000 Model Optical Microscope with Photographic equipment
  2. Trinocular optical microscope design
  3. Different optical lenses
fac
High vacuum Furnace
  1. High vacuum Furnace
  2. Diffusion Pump: Size: 4 – ½ inch
  3. Pumping Speed: 500 lit/sec
  4. Ultimate Vacuum: 10-6 millibar
  5. Heater Capacity: 500 watts
  6. Liquid nitrogen trap Valves
  7. High Vacuum cooler
  8. Analog Pirani and Penning Gauge
fac
Impedance spectrometer
  1. Frequency response analyser
  2. Impedance spectrometer
  3. Frequency range 0.1Hz - 40MHz
  4. Coretech
fac
Hardness Tester
  1. Hardness Tester
fac
Battery Tester
  1. Battery Tester